Motor Configuration
Jump to navigation
Jump to search
Motor Configuration Settings
Jog Speeds
Jog Speeds are used when the user is manually moving axes via the keyboard, the interface, or function keys.
Note: all Jog Speeds are defined in the units from Motors.xml.
| Feature | Example | ODIS-IC? | ODIS-NDT? | Description |
|---|---|---|---|---|
| Slow | N/A | x | x | Sets the Slow jog speed for each axis. |
| Medium | N/A | x | x | Sets the Medium jog speed for each axis. |
| Fast | N/A | x | x | Sets the Fast jog speed for each axis. |
| Acceleration | N/A | x | x | Sets the Acceleration used for each axis when starting motion. |
| Invert Controls | N/A | x | x | |
| Invert Function Keys | N/A | x | x | Invert the function key direction assignments. E.g. normal F1 jogs the X axis negative and F2 jogs the X-axis positive. This would reverse the effect. |
Min/Max Speeds
This defines the hard limits on motion per axis. No setting will exceed the min/max speeds once set.
| Feature | Example | ODIS-IC? | ODIS-NDT? | Description |
|---|---|---|---|---|
| Min Velocity | N/A | x | x |
Home/Init Speeds
Defines the speeds used when Initializing or Homing motion. Also used when recalling Scan Positions (e.g. Scan Start, Scan Center, etc.)
| Feature | Example | ODIS-IC? | ODIS-NDT? | Description |
|---|---|---|---|---|
| Velocity | N/A | x | x |
Initialization
Determines Initialization order and procedure on each axis.
| Feature | Example | ODIS-IC? | ODIS-NDT? | Description |
|---|---|---|---|---|
| Axis | N/A | x | x |