(Created page with "This section controls various configuration settings for A/D, P/R and Hardware acceleration. ===Acquisition=== thumb ;Try to use Fast Downloading :If checked, the data download from the A/D will start immediately when the board is armed. If the data download rate is low, this may cause DMA timeout errors. ;Disable Burst DMA :This option is set at the factory and should not be change...")
 
No edit summary
Line 3: Line 3:
===Acquisition===
===Acquisition===
[[File:ConfigurationInstrumentsAD.png|thumb]]
[[File:ConfigurationInstrumentsAD.png|thumb]]
;Try to use Fast Downloading
====Try to use Fast Downloading====
:If checked, the data download from the A/D will start immediately when the board is armed.  If the data download rate is low, this may cause DMA timeout errors.
If checked, the data download from the A/D will start immediately when the board is armed.  If the data download rate is low, this may cause DMA timeout errors.
;Disable Burst DMA
====Disable Burst DMA====
:This option is set at the factory and should not be changed.
This option is set at the factory and should not be changed.
;Discard Follower Data
====Discard Follower Data====
:If checked the preliminary TOF image will be discarded.
If checked the preliminary TOF image will be discarded.
;Disable Advanced Follower features
====Disable Advanced Follower features====
:If checked, Follower gates will collect TOF data only.
If checked, Follower gates will collect TOF data only.
;Match Thickness Type on Parent
====Match Thickness Type on Parent====
:If checked, the Thickness type being collected will be matched on the parent Follower (e.g. Peak-to-Peak, Edge-to-Edge, etc), rather than always using the Edge crossing.  This will be disabled if the "Disable Advanced Follower Features" option is checked.
If checked, the Thickness type being collected will be matched on the parent Follower (e.g. Peak-to-Peak, Edge-to-Edge, etc), rather than always using the Edge crossing.  This will be disabled if the ====Disable Advanced Follower Features" option is checked.====
;Ignore Peak Thresholds
Ignore Peak Thresholds
:If checked peak amplitude data will be collected regardless of threshold size. Rising/Falling edge TOF is not valid while this checkbox is checked.
If checked peak amplitude data will be collected regardless of threshold size. Rising/Falling edge TOF is not valid while this checkbox is checked.
;Enable Gate Gains
====Enable Gate Gains====
:If checked, the user can adjust the gain on the waveform within a gate region.
If checked, the user can adjust the gain on the waveform within a gate region.
;Always use Software Trigger when not scanning
====Always use Software Trigger when not scanning====
:If checked, the digital oscilloscopes will always be triggered by ODIS when not in a scan, at a rate of approximately 20 times a second (this will vary depending on scope and gate settings).  The trigger setting for the board is ignored until the scan starts.  Whether or not a board actually triggers depends on if it is enabled and if appropriate trigger connections and pulser/receiver settings are present.
If checked, the digital oscilloscopes will always be triggered by ODIS when not in a scan, at a rate of approximately 20 times a second (this will vary depending on scope and gate settings).  The trigger setting for the board is ignored until the scan starts.  Whether or not a board actually triggers depends on if it is enabled and if appropriate trigger connections and pulser/receiver settings are present.
;Allow different trigger modes per channel
====Allow different trigger modes per channel====
:If checked, the default trigger mode can be overridden by selecting the trigger modes via the [[Digital Oscilloscope]].
If checked, the default trigger mode can be overridden by selecting the trigger modes via the [[Digital Oscilloscope]].
;Don't trigger on channels that are not visible
====Don't trigger on channels that are not visible====
:If checked, only the currently visible Scope tab will update when idle.  Other channels will not be triggered.
If checked, only the currently visible Scope tab will update when idle.  Other channels will not be triggered.
;A/D Encoder resolutions
====A/D Encoder resolutions====
:This sets the counts per physical unit that the A/D board(s) use to to calculate increments when using [[Triggering#Pulse-On-Position (Encoder Triggering)|Encoder Triggering]].
This sets the counts per physical unit that the A/D board(s) use to to calculate increments when using [[Triggering#Pulse-On-Position (Encoder Triggering)|Encoder Triggering]].


===P/R===
===P/R===

Revision as of 14:56, 14 May 2025

This section controls various configuration settings for A/D, P/R and Hardware acceleration.

Acquisition

ConfigurationInstrumentsAD.png

Try to use Fast Downloading

If checked, the data download from the A/D will start immediately when the board is armed. If the data download rate is low, this may cause DMA timeout errors.

Disable Burst DMA

This option is set at the factory and should not be changed.

Discard Follower Data

If checked the preliminary TOF image will be discarded.

Disable Advanced Follower features

If checked, Follower gates will collect TOF data only.

Match Thickness Type on Parent

If checked, the Thickness type being collected will be matched on the parent Follower (e.g. Peak-to-Peak, Edge-to-Edge, etc), rather than always using the Edge crossing. This will be disabled if the ====Disable Advanced Follower Features" option is checked.==== Ignore Peak Thresholds If checked peak amplitude data will be collected regardless of threshold size. Rising/Falling edge TOF is not valid while this checkbox is checked.

Enable Gate Gains

If checked, the user can adjust the gain on the waveform within a gate region.

Always use Software Trigger when not scanning

If checked, the digital oscilloscopes will always be triggered by ODIS when not in a scan, at a rate of approximately 20 times a second (this will vary depending on scope and gate settings). The trigger setting for the board is ignored until the scan starts. Whether or not a board actually triggers depends on if it is enabled and if appropriate trigger connections and pulser/receiver settings are present.

Allow different trigger modes per channel

If checked, the default trigger mode can be overridden by selecting the trigger modes via the Digital Oscilloscope.

Don't trigger on channels that are not visible

If checked, only the currently visible Scope tab will update when idle. Other channels will not be triggered.

A/D Encoder resolutions

This sets the counts per physical unit that the A/D board(s) use to to calculate increments when using Encoder Triggering.

P/R

If Idle, Disable P/Rs
This option can be used to turn off the P/R(s) after a certain time has passed without any activity detected. This helps prevent long-term wear on the pulser and transducers. Set to "Never" to keep the pulser on at all times. If a scan is running, this parameter is ignored.
Clamp Pulser Energy
This is a factory setting and should not be changed.

GPU